Item | Electrical characteristics |
lPN/Primary nominal current | 500V |
IPM/Primary curent measuring range | 0~±750V |
Vc /Supply voltage | ±(15~24)(1±5%)V |
IsN /Output current | 50mA |
δi/Accuracy(excluding offset) | ≤±1%(@+25℃,±VPN) |
δz/Electrical offset | ≤±0.25mA(@+25℃ |
δL/Linearity error | ≤0.1% |
δzt/Temperature ceficient of δzt | ≤±0.75mA(-40℃~+25℃,+25℃~+85℃) |
T,/Step response time to 90 % of lPN | NVCT.XXXX-13/R≤160us(dv/dt≥1000V/us) NVCT.XXXX-13/SP2R ≤50us(dv/dt≥1000V/us); |
lc/Current consumption | ≤45mA+Isw(@±24V,+25℃) |
Ris/Isolation resistance | 500MΩ@2500V兆欧表。 |
Ua/Voltage for AC insulation test | 6kV/50Hz/1min |